| Transmisión diferencial de sobrecarga térmica para usar con fusible. |
| Compensated relays with manual or automatic reset, with relay trip indicator, for AC or DC. |
| Rango de ajuste de retraso |
|
Para usar con |
Referencia |
Peso |
| aM |
gG |
BS88 |
Contactor LC2- |
|
|
| A |
A |
A |
A |
|
|
|
| Clase 10A(1)con conexión por terminales de sujetadores ajustables |
| 0.10...0.16 |
0.25 |
2 |
- |
D09...D38 |
CLRD-01 |
0.124 |
| 0.16...0.25 |
0.5 |
2 |
- |
D09...D38 |
CLRD-02 |
0.124 |
| 0.25...0.40 |
1 |
2 |
- |
D09...D38 |
CLRD-03 |
0.124 |
| 0.40...0.63 |
1 |
2 |
- |
D09...D38 |
CLRD-04 |
0.124 |
| 0.63...1 |
2 |
4 |
- |
D09...D38 |
CLRD-05 |
0.124 |
| 1...1.7 |
2 |
4 |
6 |
D09...D38 |
CLRD-06 |
0.124 |
| 1.6...2.5 |
4 |
6 |
10 |
D09...D38 |
CLRD-07 |
0.124 |
| 2.5...4 |
6 |
10 |
16 |
D09...D38 |
CLRD-08 |
0.124 |
| 4...6 |
8 |
16 |
16 |
D09...D38 |
CLRD-10 |
0.124 |
| 5.5...8 |
12 |
20 |
20 |
D09...D38 |
CLRD-12 |
0.124 |
| 7...10 |
12 |
20 |
20 |
D09...D38 |
CLRD-14 |
0.124 |
| 9...13 |
16 |
25 |
25 |
D12...D38 |
CLRD-16 |
0.124 |
| 12...18 |
20 |
235 |
32 |
D18...D38 |
CLRD-21 |
0.124 |
| 16...24 |
25 |
50 |
50 |
D25...D38 |
CLRD-22 |
0.124 |
| 23...32 |
40 |
63 |
63 |
D25...D38 |
CLRD-32 |
0.124 |
| 30...38 |
50 |
80 |
80 |
D32 and D38 |
CLRD-35 |
0.124 |
| 17...25 |
25 |
50 |
50 |
D40...D90 |
CLRD-322 |
0.510 |
| 23...32 |
40 |
63 |
63 |
D40...D90 |
CLRD-3353 |
0.510 |
| 30…38 |
40 |
100 |
80 |
D40...D90 |
CLRD-3355 |
0.510 |
| 37...50 |
63 |
100 |
100 |
D40...D90 |
CLRD-3357 |
0.510 |
| 48...65 |
80 |
100 |
100 |
D50...D90 |
CLRD-3359 |
0.510 |
| 55...70 |
80 |
125 |
125 |
D50...D90 |
CLRD-3362 |
0.510 |
| 63...80 |
100 |
125 |
15 |
D65 and D96 |
CLRD-3363 |
0.510 |
| 80...104 |
125 |
160 |
160 |
D80 and D96 |
CLRD-3365 |
0.510 |
| 80...104 |
125 |
200 |
160 |
D115 and D150 |
CLRD-4365 |
0.900 |
| 95...120 |
160 |
200 |
200 |
D115 and D150 |
CLRD-4367 |
0.900 |
| 110...140 |
100 |
250 |
200 |
D150 |
CLRD-4369 |
0.900 |
| 80...104 |
125 |
160 |
160 |
(2) |
CLRD-33656 |
1.000 |
| 95...120 |
160 |
200 |
200 |
(2) |
CLRD-33676 |
1.000 |
| 110...140 |
|
250 |
200 |
(2) |
CLRD-33696 |
1.000 |
| Clase 10A(1) con conexión de terminales elásticas (para montaje directo sólo en el contactor) |
| 0.10...0.16 |
0.25 |
2 |
- |
D09...D38 |
CLRD-013 |
0.140 |
| 0.16...0.25 |
0.5 |
2 |
- |
D09...D38 |
CLRD-023 |
0.140 |
| 0.25...0.40 |
1 |
2 |
- |
D09...D38 |
CLRD-033 |
0.140 |
| 0.40...0.63 |
1 |
2 |
- |
D09...D38 |
CLRD-043 |
0.140 |
| 0.63...1 |
2 |
4 |
- |
D09...D38 |
CLRD-053 |
0.140 |
| 1...1.7 |
2 |
4 |
6 |
D09...D38 |
CLRD-063 |
0.140 |
| 1.6...2.5 |
4 |
6 |
10 |
D09...D38 |
CLRD-073 |
0.140 |
| 2.5...4 |
6 |
10 |
16 |
D09...D38 |
CLRD-083 |
0.140 |
| 4...6 |
8 |
16 |
16 |
D09...D38 |
CLRD-103 |
0.140 |
| 5.5...8 |
12 |
20 |
20 |
D09...D38 |
CLRD-123 |
0.140 |
| 7...10 |
12 |
20 |
20 |
D09...D38 |
CLRD-143 |
0.140 |
| 9...13 |
16 |
25 |
25 |
D12...D38 |
CLRD-163 |
0.140 |
| 12...18 |
20 |
235 |
32 |
D18...D38 |
CLRD-213 |
0.140 |
| 16...24 |
25 |
50 |
50 |
D25...D38 |
CLRD-223 |
0.140 |
| Retraso de sobrecarga térmica para usar con cargas desequilibradas |
| Clase 10A(1) con conexión por terminales de sujetadores ajustables |
| Se cambia el prefijo en las referencias de arriba desde LRD(excepto LRD-4...) hasta LRD-D |
| Ejemplo: LRD-01 se convierte LR3-D01 |
| Retraso de sobrecarga térmica para usar en suministros de 1000V |
| Clase 10A(1) con conexión por terminales de sujetadores ajustables |
| (1) Estándar IEC947-1 especificando un tiempo de circulación para 7.2 veces de ajuste de corriente Ig: |
| Clase 10A: entre 2 y 10 segundos. |
| (2) montaje independiente |